Connecting to Industrial HiVision
Using HiView, you can start the Industrial HiVision GUI without installing Industrial HiVision. You can use the URL connection to Industrial HiVision to monitor the status of your network. This function offers you a limited version of the Industrial HiVision GUI.
To establish a connection to the Industrial HiVision "Web server", in the Industrial HiVision dialog, perform the following steps:
- Mark the checkbox.
- Mark the checkbox.
- Record the following settings:
-
-
-
Starting with Industrial HiVision release 8.0, you can change the value of the . Record this value if you changed the default port value. If you changed the from the default port value, then it is necessary to connect to the configured port.
Note:
You can find the default port values in the Industrial HiVision manual, chapter A.5 "Ports used".
Perform the following steps in the HiView Devices tab.
In the following examples, these values are used:
- The is https.
- The IP address of the network management station is 10.0.1.159.
- The is 11194 .
- For the second example, the was changed to 10000.
When the is set to the default port value, perform the following steps:
- In the "URL" field, enter the following information: ://Management Station IP Address:.
For example, https://10.0.1.159: 11194 .
- Press the "Return" key.
When you changed the from the default port value, perform the following steps:
- In the "URL" field, enter the following information: ://Management Station IP Address:?project-data-port=.
For example, https://10.0.1.159:11194?project-data-port=10000.
- Press the "Return" key.
Note:
The Web server port value that Industrial HiVision uses is version-dependent. You find the port that Industrial HiVision uses in the settings under . Starting with Industrial HiVision version 7.0 you find the current port number in the dialog.
|